Sonatest Prisma Flaw Detector

$11,000.00 Original price was: $11,000.00.$5,500.00Current price is: $5,500.00.
In Stock
  • Manufacturer: Sonatest
  • Model: Prisma Flaw Detector
  • Included: Dual UT Channels with: A-Scan recording, 2 Axis Encoding, Interface Triggering (IFT); 16:16, manual PA., A,B & C Scan Displays, USB Stick (8GB), Couplant, User Manual, 2 point neck harness, Lithium Ion Battery Packs (x2), External battery charger, Power cord & supply adaptor, Screen Protector, Transport Case (Airplane Carry on size)
In Stock
SKU: SPFD
Category:
Brand:

Description

Sonatest Prisma Flaw Detector offers the end user, outstanding performance in the field together with the flexibility and capability to step up from using a high-end ultrasonic flaw detector to an instrument with phased array functionality.

Sonatest Prisma Flaw Detector provides the user with an ultrasonic Phased Array flaw detector. Sonatest Prisma Flaw Detector tool contains PA capability from 16:16 manual to 16:64, with 2D encoding.

Sonatest Prisma Flaw Detector an updated imaging system that allows the A scan, B scans and C scans to be used. The 3D ScanPlan includes the part, weld, wedge, probe and scan coverage. Sonatest Prisma Flaw Detectorcan be used in different areas of applications, such as aerospace, marine, composite and corrosion applications. In addition, the Prisma Phased Array equipment comes with numerous palettes for all scans.

 

Sonatest Prisma Flaw Detector Features:

  • Great PA capability from 16:16 manual through to 16:64 with 2D encoding.
  • UT to PA – and back
  • Enhanced Imaging Capability enables A-Scan, B Scans and C-Scans.
  • Advanced display modes include smoothing, contouring, averaging, envelope
  • A-Scan resolution  – up to 8192 points
  • New Configuration Wizard helps the technican to get the best out of the Prisma
  • TOFD is on board – so need to have extra instrumentation for TOFD Inspection.

 

Sonatest Prisma Flaw Detector Included:

  • Dual UT Channels with: A-Scan recording, 2 Axis Encoding, Interface Triggering (IFT)
  • 16:16, manual PA.
  • A,B & C Scan Displays
  • USB Stick (8GB)
  • Couplant
  • User Manual
  • 2 point neck harness
  • Lithium Ion Battery Packs (x2)
  • External battery charger
  • Power cord & supply adaptor
  • Screen Protector
  • Transport Case (Airplane Carry on size)

 

You may also be interested in Sonatest Masterscan D70 Flaw Detector

 

Specifications:

Conventional UT Phased Array
Pulsers
Configuration 2 UT Channels 16:16 or 16:64
Test Mode Pulse-Echo, Transmit/Receive and TOFD Pulse-Echo, Transmit/Receive
Transducer Socket LEMO 1 or BNC I-PEX
Pulse Voltage -100V to -450V (in steps of 10V) -25V to -75V (in steps of 5 V)
PRF 1Hz to 1500Hz 1Hz to 5000Hz
Pulse Shape Negative Square Wave (with ActiveEdge) Negative Square Wave (with ActiveEdge)
Pulse Width Adjustable: Spike to 2000ns (2.5ns resolution) Adjustable: Spike to 1000ns (2.5ns resolution)
Edge Time 15ns in 50Ω load @200V 12ns in 50Ω load @50V
Output Impedance <10Ω
Trigger Synchronisation On encoder resolution or internal PRF (both encoded or not) On encoder resolution or internal PRF (not encoded)
Focus Delay Range n/a 0 to 10μs (2.5ns resolution)
Damping Resistor Selectable: 50Ω or 400Ω n/a
Receivers
Gain Range 100dB (0.1dB steps) Analogue Gain 0 to 76 dB (0.1 dB steps), Analogue Gain
Max Input Voltage 25Vp-p 200mVp-p
Input Impedance 1kΩ (pitch and catch) 200Ω
Bandwidth 200kHz to 22MHz (-3dB) 200kHz to 14MHz
Analog Filters 4 (automatic or manual) 3 (automatic)
Digital Filters 10 (automatic or manual) 10 (automatic or manual)
Rectification Full wave, positive, negative, none (RF) Full wave, positive, negative, none (RF)
Signal Enhancement Digital filters, Smoothing, Contouring, Rejection, Averaging Digital filters, Smoothing, Contouring, Rejection
Focus Delay Range n/a 0 to 10μs (16ns resolution interpolated to 3.8ns)
Data Acquisition
Architecture 2 channels, true 200MHz sampling rate 16 Channels, Full digital Delay & Sum
Digitizer Resolution 12bit ADC 12bit ADC
Amplitude Measurement [0% to 100%] or [0% to 150%] FSH [0% to 100%] or [0% to 150%] FSH
Data Processing 16bits/sample 16bits/sample
Data Recording Full raw data recording (plus sub-sampling options) Full raw data recording (plus sub-sampling options)
File Size up to 3GB up to 3GB
Digitizing Frequency 50MHz, 100MHz, 200MHz 65MHz
Focal Laws n/a 128
Focusing Mode n/a Natural or constant depth/path/offset
Max A-Scan Length 8192 samples 4096 samples
Sub-Sampling 1:1 to 1:128 1:1 to 1:128
Reference Initial Pulse or Gate/IFT supported Initial Pulse or Gate/IFT supported
Trigger Sync. Encoder or Internal Encoder or Internal
Scan & Views
Supported Scans A-Scan & TOFD S-Scan or L-Scan
Number of Scans up to 2 1 (with up to 3 extracted A-Scans)
Views A, B, C-Scan, Merged & TOFD A, B, C, L, S-Scan, Merged plus true TOP & END
Colour Maps up to 10 up to 10
Number of Layouts 18 35

Additional information

Weight 10 kg
Dimensions 60 × 60 × 50 cm

Reviews

There are no reviews yet.

Be the first to review “Sonatest Prisma Flaw Detector”

Your email address will not be published. Required fields are marked *